[Cites 0, Cited by 0]
[Entire Act]
State of Punjab - Section
Section 24 in Punjab Urban Planning and Development Building Rules, 2018
24. Public Buildings.
- The public buildings of various types shall be governed by the following norms, namely:-| Table 26: Community Centre, Public ConcertHall or Auditorium, Museum, Gymnasium or Public Exhibition | ||
| S. No. | Parameter | Permissible Limits |
| I. | Minimum Site area | 2000 sq.m |
| II. | Minimum Approach Road | Within Master Plan -18m (60'-0") |
| Outside Master Plan-12m (40'-0") | ||
| III. | Maximum Ground Coverage | 40% |
| IV. | Maximum Floor Area Ratio | 1:1 |
| V. | Maximum Height of Building | No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms. |
| VI. | Parking | 3[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).]. |
| VII. | Setbacks around buildings | Refer sub-rule (1) of rule 26 of these buildingrules. |
| Table 27: Religious Building | |||
| S. No. | Parameter | Permissible Limits | |
| I. | Minimum Approach Road and Site area | Plot size minimum 1000 sq. mts upto 2000 sq.m | 12m (40'-0") |
| Plot size above 2000 sq.m | 18m (60'-0") | ||
| II. | Maximum Ground Coverage | 40% of site area | |
| III. | Maximum Floor Area Ratio | 1:1.0 | |
| IV. | Maximum Height of Building | No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms. | |
| V. | Parking | 2[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).]. | |
| VI. | Setbacks around buildings | Refersub-rule (1) of rule 26of thesebuilding rules. |
| Table 28: Public Offices | |||
| S. No. | Parameter | Permissible Limits | |
| I. | Minimum Site area | 1000 sq.m | |
| II. | Minimum Approach Road | 18m | |
| III. | Maximum Ground Coverage | 40% of plot area | |
| IV. | Maximum Floor Area Ratio | Minimum approach road18m 1:2Minimum approach road 30m 1:2.5 | |
| Minimum approach road 45m Unlimited* | |||
| V. | Maximum Height of Building | No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms. | |
| VI. | Parking | 2[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).]. | |
| VII. | Setbacks around buildings | Refersub-rule (1) of rule 26of thesebuilding rules. |