Section 54(8) in Kerala Municipality Building Rules, 1999

(8)All buildings in Group B (educational) and Group C (medical/hospital) occupancies, whatever may be its built-up area and other buildings in Group E (office or business occupancies) exceeding 1500 sq. metres built up area special provision shall be made for recycling and reusing of waste water generated out of the use of water in the said building.] [Inserted by Notification No. S. R. O. No. 676/2017, dated 31.10.2017.]
(1) (2) (3) (4a) (4b) (4c)
Sl. No. Fitments Assembly occupancies Assembly Assembly Assembly
Theatres, Auditorium, art Galleries, Libraries,Restaurants, wedding halls, Community halls Bus Terminal Railway Station Air ports
1 Water Closet 1 per 200 males or part thereof and 1 per 100females or part thereof 4 for first 1000 persons and 1 for everysubsequent 1000 persons or part thereof 5 for first 1000 persons and 1 for everysubsequent 1000 persons or part thereof 5 for first 1000 person and 1 for everysubsequent 1000 persons or part thereof
2 Urinals 1 per 50 person or part thereof 6 for first 1000 persons and 1 for everysubsequent 1000 persons or part thereof 6 for first 1000 person and 1 for everysubsequent 1000 persons or part thereof 6 for first 1000 person and 1 for everysubsequent 1000 persons or part thereof
3 Wash Basin 1 for every 200 males and 1 for every 200females 4 wash basin each in male and female toiletstalls 4 wash basin each in male and female toiletstalls 4 wash basin each in male and female toiletstalls
4 Bath        
Sl. No. Hotels Storage occupancy Educational Educational Office/Mercantile Occupancies Industrial Occupancies
Boarding Institutions Other Educational Institutions
  (5) (6) (7) (8) (9) (10)
Water Closet 1 per 100 males and 1 per 100 females 1 per 50 males and 1 per 25 females 1 per 10 boys and 1 per every 8 girls 1 per 40 boys and 1 per every 25 girls 1 for every 25 males or part thereof and 1 forevery15 females or part thereof 1 per every 25 males and 1 per every 15 females
Urinals 1 per water closet fro males 1 per 100 males or part thereof 1 per every 25 boys 1 per every 50 boys 1 for every 25 person or part thereof 1 for every 25 person or part thereof
Wash Basin 1 per water closet for males and 1 per watercloset for females   1 per 10 boys and 1 per every 10 girls 1 per every 40 boys and 1 per every 40 girls Preferably one on each floor  
Bath 1 per 100 persons   1 per 10 boys and 1 per 100 persons 1 per every8 girls     As required for particular trades or occupancies
Sanitation requirements for Medical/Hospital Occupancy
Sl. No. Fitments Hospitals with indoor patients ward Hospitals with outdoor patients Administration Building
For males and females For males For females For male personnel For female personnel
(1) (2) (3) (4) (5) (6) (7)
1 Water closet One for every 8 beds or part thereof One for every 100 persons or part thereof Two for every 100 persons or part thereof One for every 25 persons or part thereof One for every 15 persons or part thereof
2 Ablution taps One in each water closet plus one water tap withdraining arrangement in the vicinity of water closets and urinalsfor every 50 beds or part thereof One in each water closet. One water tap withdraining arrangements shall be provided for every 50 persons orpart thereof in the vicinity of water closet and urinals One in each water closet. One water tap withdraining arrangements shall be provided for every 50 persons orpart thereof in the vicinity of water closet and urinals
3 Wash basins Two upto 30 beds; add one for every additional30 beds or part thereof One for every 100 persons or part thereof One for every 25 persons of part thereof 30 bedsor part thereof
4 Baths with shower One bath with shower for every 8 beds or partthereof   One on each floor
5 Bed pan washing sink One for each ward    
6 Cleaners sink One for each ward minimum One per floor minimum One per floor minimum
7 Kitchen sink & dish washers (where kitchen isprovided) One for each ward    
8 Urinals   One for every 50 persons or part thereof Nil up to 6 persons1for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to200 persons add at the rate of 3%. For over 200 persons add atthe rate of 2.5%.