39. Slenderness ratio - [Section 4(2)(1) and (h)].

- Slenderness ratio must not exceed 12 and reduction in the permissible pressure figure given for slenderness ratio not exceeding six shall be carried on according to the table given below :
Slenderness ratio Reduction in maximum permissible pressure to slendernessratio exceeding six per cent
7 10
8 20
9 30
10 40
11 50
12 60
Explanation - Slenderness ratio on any storey height of wall or a pier is the ratio of the effective storey height to the thickness of the wall. The effective storey height to be taken as :
For wall with no lateral support at top 1½ actual storey height.
For wall with lateral support at top ¾ actual storey height.
Piers with no lateral support at top 2 actual storey height.