State of Odisha - Section

Section 19 in The Orissa Aerial Ropeways Rules, 1959

19.

A ropeway shall be constructed with minimum factors of safety as follows :
  Ropes Minimum factor of safety at the point of maximumstress
  Mono cable 5
  Bi-cables
  Carrying rope 4
  Hauling rope 5
  Structural steel work 4
  Other ropeway fittings 5
Trestles foundations must be sufficiently large to give a moment 50 per cent greater than the overturning moment due to a wind pressure of 15 lbs. per square foot on the aerial line supports and 30 lbs. per square foot on aerial ropeway supports. For tall trestles guy ropes may be used.