[Cites 0, Cited by 0]
[Entire Act]
State of West Bengal - Section
Section 127 in Kolkata Municipal Corporation Building Rules, 2009
127. Minimum Width provisions.
- The following provisions for minimum width shall be made :-Table - 8A| Category of Building | Height of the Building, (Mtrs.) | Width of the Stairway (Mtrs.) | No. of Staircase |
| Residential | Above 7.00 | 1.00 | 1 |
| Above 7.00 and Up to 10.00 | 1.0 m. with landing 1.2 m. having maximum 150sq.m. floor plate in each floor | 1 | |
| Above 10.00 and Upto 15.50 | 1.1 m. with landing 1.35 m. having maximum 150sq.m. floor plate in each floor | 1 | |
| Above 15.50 and Upto 20.00 | 1.25 | 2 | |
| Above 20.00 and Upto 25.50 | 1.25 | 2 | |
| Above 25.50 and Up to 40.00 | 1.25 | 2 | |
| 40.00 and above | 1.50 | 2 |
| Category of Building | Area per floor | Width of the Stairway (Mtrs.) | Minimum No. of Staircase (Height upto 12.5Mtrs.) | Minimum No. of Staircase (Height Above 12.5Mtrs.) |
| Educational | Upto 500 sq. m. | 1.5 | 1 | 2 |
| Above 500 sq. m. | 1.8 | 2 | 2 | |
| Assembly | Upto 500 sq. m. | 1.50 | 1 | 2 |
| Above 500 sq. m. | 2.0 | 2 | 2 | |
| Institutional | Upto 500 sq. m. | 1.50 | 1 | 2 |
| Above 500 sq. m. | 2.0 | 2 | 2 | |
| Business | Upto 500 sq. m. | 1.50 | 1 | 2 |
| Above 500 sq. m. | 1.50 | 2 | 2 | |
| Mercantile (Retail) | Up to 500 sq. m. | 1.80 | 2 | 2 |
| Above 500 sq. m. | 2.00 | 2 | 2 |
| Category of passage or corridor | Minimum width (m.) |
| Passage connecting vertical exit and thetenement or units | Not less than the width of each stairwayspecified under Table 8A and 8B |
| Passage within an apartment | 1.0 m, |
| Passage giving accessto shops in a mercantile building -(a) shops on one sideonly(b) shops on both side | 2.03.0 |
| Passage in a business building | 2.5 |