State of West Bengal - Subsection

Section 69(1) in Kolkata Municipal Corporation Building Rules, 2009

(1)The Floor Area Ratios shall be as specified in Table 3 below: -Maximum Permissible Floor Area Ratio
    Use Groups of Buildings*
SI. No. Width of Means of Access (m) Residential Buildings Educational Buildings Industrial, Storage and Hazardous Buildings Assembly, Institutional Business, MercantileBuildings including Mixed use Buildings.
1. Upto 2.4 Nil Nil Nil Nil
2. Above 2.4 to 3.5 1.25 Nil Nil Nil
3. Above 3.5 to 7.0 1.75 Nil Nil Nil
4. Above 7.0 to 9.0 2.00 2.00 Nil Nil
5. Above 9.0 to 15.0 2.25 2.25 2.00 2.00
6. Above 15.0 to 20.0 2.50 2.50 2.00 2.25
7. Above 20.0 to 24.0 2.75 2.75 2.00 2.50
8. Above 24.0 3.00 3.00 2.00 2.75
Provided that the width of means of access mentioned under Table 3 is to be taken as the average road width abutting the entire length of the plot.