State of Kerala - Section

Section 181 in Kerala Factories Rules, 1957

181. Entry in to vessels.

(a)Before any person enters, for any purpose except that of rescue, any absorber, boiler, culvert, drain, flue, gas purifier, sewer, still tank, tower, vitriol chamber or other places where there is reason to apprehend the presence of dangerous gas or fume, a responsible person appointed in writing by the occupier for the purpose shall personally examine such place and shall certify in writing in a book kept for the purpose either that such place is isolated and sealed from every source of such gas or fume and free from danger, or that it is not so isolated and sealed and free from danger. No person shall enter such place which is certified not to be so isolated and sealed and free from danger unless he is wearing a breathing apparatus, and (where there are no cross stays or obstructions likely to cause entanglement) a life belt, the free end of the rope attached to which shall be left with a man outside whose sole duty shall be to keep watch and to draw out the wearer if he appears to be affected by gas of fume. The belt and rope shall be so adjusted and worn that the wearer can be drawn up head foremost through any manhole or opening.
(b)A person entering for the purpose of rescue any such place for which a clearance certificate has not been issued shall wear a breathing apparatus and a life - belt in the manner specified.