Section 98(4) in Cuttack Development Authority (Planning and Building Standards) Regulations, 2001

(4)Exits shall be so located that the travel distance on the floor shall not exceed twenty metres in case of residential, educational, institutional and hazardous occupancies and thirty metres in the case of assembly, business, mercantile, industrial and storage occupancies. Wherever more than one exit is required for a floor of a building, exit shall be placed at a reasonable distance from each other as possible. All the exits shall be accessible from the entire floor area at all floor level.