Section 89 in The M.P. Bhumi Vikas Rules, 1984
89. Requirements of Sanitary fittings.
- The sanitary fittings and installations for different occupancies shall be as given in Tables 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 and 25.Table-14Sanitation Requirements for shops and Commercial Offices| S.No. | Fitments | For Personnel |
| 1. | Water closet | One for every 25 persons or part thereof exceeding 15(including employees and customers). |
| For female personnel 1 for every 15 persons or part thereofexceeding 10. | ||
| 2. | Drinking Water Fountain | One for every 100 persons with a minimum of one on eachfloor. |
| 3. | Wash Basin | One for every 25 persons or part thereof. |
| 4. | Urinals | Same as at serial No. 3 of Table 19. |
| 5. | Cleaner's Sink | One per floor minimum, preferably in or adjacent to sanitaryrooms. |
| S. No. | Fitments | For residential public and staff | For public rooms | For non-residential staff | ||
| For males | For females | For male | For female | |||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 1. | Water Closet | 1 per 8 persons omitting occupants of the room with attachedwater closet, minimum of 2 in both sexes lodged | 1 per 100 persons upto 400 persons for over 400 add at therate of 1 per 250 persons or part thereof | 2 for 100 persons up to 200 persons over 200 add at the rateof 1 per 100 or part thereof | 1 for 1-152 for 16-353 for 36-654 for 66-100 | 1 for 1-122 for 13-253 for 26-404 for 41-57 |
| 2. | Ablution taps | 1 in each water closet | 1 in each water closet | 1 in each water closet | 1 in each water closet | 1 in each water closet |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetand urinal. | ||||||
| 3. | Urinals | 1 for 50 persons or part thereof | PersonsNil up to 61 for 7-202 for 21-403 for41-704 for 71-100 | |||
| 4. | Wash basins | 1 per 10 persons omitting the wash basins installed in theroom suites | 1 per water closet and urinal provided | 1 for water closet provided | Persons1 for 1-152 for 16-353 for 36-654 for66-100 | Persons1 for 1-122 for 13-253 for 26-404 for41-575 for 58-776 for 78-100 |
| 5. | Baths | 1 per 10 persons omitting occupants of the room with bath insuite | ||||
| 6. | Slop sinks | 1 for 30 bed rooms (one per floor minimum) | ||||
| 7. | Kitchen sinks | 1 in each kitchen | 1 in each kitchen | 1 in each kitchen | 1 in each kitchen | 1 in each kitchen |
| No. | Fitments | Nursery Schools | Boarding Institution | Other Educational Institutions | ||
| For Boys | For Girls | For Boys | For Girls | |||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 1. | Water Closet | One per 30 pupils or part thereof | One per 8 pupils or part thereof | One per 6 pupils or part thereof | One per 80 pupils or part thereof | One per 50 pupils or part thereof |
| 2. | Ablution Tap | One in each water closet | One in each water closet | One in each water closet | One in each water closet | One in each water closet |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity. | ||||||
| 3. | Urinals | One per 25 pupils or part thereof | One per 20 pupils or part thereof | |||
| 4. | Wash Basin | One per 30 pupils or part thereof | One per 8 pupils or part thereof | One per 60 pupils or part thereof | One per 80 pupils or part thereof | One per 80 pupils or part thereof |
| 5. | Baths | One bath sink per 40 pupils | One or every 8 pupils or part thereof | One for every 6 pupils or part thereof | Nil | Nil |
| 6. | Drinking water fountains | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof |
| 7. | Cleaners sink | One per floor minimum | One per floor minimum | One per floor minimum | One per floor minimum |
| S. No. | Fitments | Hospitals with indoor patient wards | Hospitals with outdoor patient wards | Administrative building | ||
| For males and for females | For males | For females | For male personnel | For female personnel | ||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 1. | Water Closet | One for every 8 beds or part thereof | One for every 100 persons or part thereof | Two for every 100 persons or part thereof | One for every 25 persons or part thereof | One for every 15 person of part thereof |
| 2. | Ablution Taps | One in each water Closet | One in each water Closet | One in each water Closet | One in each water Closet | One in each water Closet |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetand urinals. | ||||||
| 3. | Wash Basins | 2 up to 30 bed add one for every additional 30 beds or partthereof. | One for every 100 persons or part thereof | One for every 100 persons or part thereof | One for every 25 persons or part thereof | One for every 4 persons or part thereof |
| 4. | Baths with shower | One Bath with shower for every 8 beds or part thereof | – | – | One on each floor | One on each floor |
| 5. | Bed pan washing sinks | One for each ward | – | – | – | – |
| 6. | Cleaners sink | One for each ward | One per floor minimum | One per floor minimum | One per floor minimum | One per floor minimum |
| 7. | Kitchen sinks and dish washes (where kitchen is provided) | One for each ward | – | – | – | – |
| 8. | Urinals | – | One for every 50 persons or part thereof | – | – | One up to 20 persons2-for 21-45 persons3-for 46-70person4-for 71-100 personsfor 101 to 200 persons add atthe rate of 3 percentFor over 200 persons add at the rate of2.5 percent |
| S. No. | Fitments | Doctor's Dormitories | Nurses Hostel | |
| For male staff | For female staff | |||
| 1 | 2 | 3 | 4 | 5 |
| 1. | Water closet | One for 4 persons | One for 4 persons | One for 4 persons or part thereof |
| 2. | Ablution taps | One in each water closet | One in each water closet | One in each water closet |
| 3. | Wash Basins | One for every 8 persons or part thereof | One for every 8 persons or part thereof | One for every 8 persons or part thereof |
| 4. | Baths (with shower) | One for 4 persons or part thereof | One for 4 persons or part thereof | One for 6 persons or part thereof |
| 5. | Cleaner's sinks | One per floor minimum | One per floor minimum | One per floor minimum |
| S. No. | Fitments | For males personnel | For female personnel |
| 1 | 2 | 3 | 4 |
| 1. | Water closet | One for every 25 persons or part thereof | One for every 15 persons or part thereof |
| 2. | Ablution taps | One in each water closet. | One in each water closet |
| One water tap with draining arrangement shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals. | |||
| 3. | Urinals | Nil up to 6 personsOne for 7-20 persons2 for 21-45persons3 for 46-70 persons4 for 71-100 personsFor 101to 200 persons add at the rate of 3 percent.For over 200persons add at the rate of 2.5 percent. | |
| 4. | Wash basins | One for every 250 persons or part thereof. | |
| 5. | Drinking water fountains | One for every 100 persons with a minimum of one for eachfloor. | |
| 6. | Baths | Preferably one on each floor | |
| 7. | Cleaners Sinks | One per floor minimum preferably in or adjacent to sanitaryrooms |
| S. No. | Fitments | Dwelling with individual conveniences | Dwelling without individual Conveniences |
| (1) | (2) | (3) | (4) |
| 1. | Bath Rooms | 1 provided with water tap | 1 for every three tenements |
| 2. | Water closet | 1 | 1 for every three tenements |
| 3. | Sink (or NAHANI) in the floor | 1 | |
| 4. | Water Tap | 1 | 1 with draining arrangements in each tenement in common bathrooms and common water closets |
| S. No. | Fitments | For public | For staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| 1. | Water closets | 1 per 100 persons up to 400 persons. | 3 per 100 persons up to 200 persons. | 1 for 1-15 persons2 for 16-35 persons | 1 for 1-12 persons2 for 13-25 persons |
| For over 400 persons, add at the rate of 1 per 250 persons orpart thereof. | For over 200 persons add at the rate of 2 per 100 persons orpart thereof. | ||||
| 2. | Ablution Taps | 1 in each water closet | 1 in each water closet | 1 in each water closet | 1 in each water closet |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals. | |||||
| 3. | Urinals | 1 for 50 persons or part thereof | Nil up to 6 persons.1 for 7-20 persons.2 for 21-45persons. | ||
| 4. | Wash basins | 1 for every 200 persons or part thereof. | 1 for every 200 persons part thereof. | 1 for 1-15 persons2 for 16-35 persons | 1 for 1-12 persons2 for 13-25 persons |
| 5. | Drinking water Fountains | 1 for 100 persons or part thereof |
| S. No. | Fitments | For public | For staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| 1. | Water closets | 1 per 200 persons up to 400 persons. For over 400 persons, addat the rate of 1 per 250 person or part thereof. | 1 per 100 persons up to 200 persons. For over 200 persons, addat the rate of 1 per 150 person or part thereof. | 1 for 1-15 persons2 for 16-35 persons | 1 for 1-12 persons2 for 13-25 persons |
| 2. | Ablution Taps | 1 in each water closet | 1 in each water closet | 1 in each water closet | 1 in each water closet. |
| One water tap with draining arrangements shall be provided forevery 50 per sons or part thereof in the vicinity of waterclosets and urinals. | |||||
| 3. | Urinals | 1 for 50 persons | Nil up to 6 persons1 for 7-20 persons2 for 21-45person | ||
| 4. | Wash basins | 1 for every 200 persons or part thereof. For over 400 personsadd at the rate of 1 per 250 persons or part thereof. | 1 for every 200 persons or part thereof. For over 200 personsadd at the rate of 1 per 150 persons or part thereof. | 1 for 1-15 persons2 for 16-25 persons | 1 for 1-12 persons2 for 13-25 persons |
| 5. | Cleaners Sinks | 1 per floor minimum. |
| S. No. | Fitments | For public | For staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| 1. | Water closets | 1 for 50 seats upto 200 seats.For over 200 seats add atthe rate of one per 100 seats or part thereof. | 1 for 50 seats upto 200 seats.For over 200 seats, add atthe rate of one per 100 seats or part thereof. | 1 for 1-15 persons.2 for 16-35 persons3 for 36-65persons4 for 66-100 persons | 1 for 1-12 persons2 for 13-25 persons3 for 26-40persons4 for 41-57 persons5 for 58-77 persons6 for78-100 persons |
| 2. | Ablution Taps | 1 in each water closet | 1 in each water closet | 1 in each water closet | 1 in each water closet. |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals. | |||||
| 3. | Urinals | One per 50 seats. | Nil upto 6 persons1 for 7-20 persons2 for 21-45persons3 for 46-70 persons4 for 71-100 persons | ||
| 4. | Wash basins | 1 for every water closet provided. | |||
| 5. | Kitchen sinks and dish washer | 1 in each kitchen. | |||
| 6. | Stop or service sink. | 1 in the restaurant. |
| S. No. | Fitments | For Male personnel | For Female personnel |
| (1) | (2) | (3) | (4) |
| 1. | Water closets | 1 for 1-15 persons2 for 16-35 persons3 for 36-65persons4 for 66-100 personsFor 101 to 200 persons, add atthe rate of 3 percent. For over 200 persons and at the rate of2.5 percent | 1 for 1-12 persons2 for 13-25 persons3 for 26-40persons4 for 41-57 persons5 for 58-77 persons6 for78-100 personsFor 101 to 200 persons, add at the rate of 5percent. For over 200 persons add at the rate of 4 percent. |
| 2. | Ablution Taps | 1 in each water closet | 1 in each water closet. |
| One water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand in urinals. | |||
| 3. | Urinals | Nil up to 6 persons.1 for 7-20 persons2 for 21-45persons3 for 46-70 persons4 for 71-100 personsFor 101to 200 persons add at the rate of 3 percent.For over 200persons add at the rate of 2.5 percent. | |
| 4. | Washing taps with draining arrangements | 1 for every 25 persons or part thereof. | 1 for every 25 persons or part thereof. |
| 5. | Drinking water Fountains | 1 for every 100 persons with a minimum of one on each floor. | |
| 6. | Baths (preferably showers) | As required for particular trades or occupations. |
| Sl.No. | Place | WC for Males | WC for female | Urinals for Males only |
| (1) | (2) | (3) | (4) | (5) |
| 1. | Junction station intermediate stations and bus stations. | 3 for first 1000 persons and 1 for every subsequent 1000persons or part there of. | 4 for first 1000 persons and 1 for every additional 1000persons or part thereof. | 4 for every 1000 persons and 1 for a very additional 1000persons or part thereof. |
| 2. | Terminal stations and bus terminals | 4 for first 1000 persons and 1 for every subsequent 1000persons or part thereof. | 5 for first 1000 persons and 1 for every subsequent 2000persons or part thereof. | 6 for first 1000 persons and 1 for every additional 1000persons or part thereof. |
| 3. | Domestic Airports, Min.for 200 personsfor 400 personsfor 600 personsfor 800 personsfor 1000 persons | 2*59121618 | 4*815202629 | 2*612162022 |
| 4. | International airportsfor 200 personsfor 600 personsfor 1000 persons | 61218 | 102029 | 81622 |