OBSERVATIONS:
i) Exhibit-1 (blood sample of the accused on FTA card) and Exhibit-2 (blood sample of the victim on FTA card) yielded good quality DNA and it was possible to amplify all the fifteen autosomal STR loci and amelogenin with AmpF/STR Identifiler Plus ® PCR Amplification Kit.
ii) Exhibit-3a (shirt of the victim) yielded highly degraded DNA which did not show amplification with AmpF/STR Identifiler Plus ® PCR Amplification Kit.
iii) Exhibit-3b (slacks of the victim), yielded slightly degraded DNA, however it was possible to amplify all the fifteen autosomal STR loci and amelogenin with AmpF/STR Identifiler Plus ® PCR Amplification Kit.
iv) The DNA profile obtained from exhibit-3b (slacks of the victim) matches completely with the DNA profile obtained from exhibit-1 (blood sample of the accused on FTA card) CONCLUSIONS:
On the basis of the above analysis performed on the aforesaid exhibits, it is concluded that:-
i) Exhibit-3a (shirt of the victim) yielded highly degraded DNA which did not show amplification with AmpF/STR Identifiler Plus ® PCR Amplification kit, hence no DNA profile was obtained.
ii) The DNA profile obtained from Exhibit-3b (slacks of the victim) matches completely with the DNA profile obtained from exhibit-1 (blood sample of the accused on FTA card)."