3.   Pressure   regulator   shall   conform  inlet diameter of 25.6 mm.

                                                    to   IS   9798   specification   having   an 
                                                    inlet diameter of 25.6 mm,
                                                    Schedule-B    [ See clauses 4 & 5 ]             Schedule - III    [ See clauses 4 (1) 
                                                    (Applicable   to   Parallel   Marketing         (e) & 5)
         ­­­Not in this Order­­­                    System)                                         (Applicable   to   Parallel   Marketing 
                                                    A   parallel   marketeer   under   the          System)
                                                    parallel   marketing   system  may   deal       A   Parallel   marketeer   under   the 
                                                    with--                                           parallel marketing system shall deal 
                                                    (a)   cylinder   of   any   size,   shape,      with and use:
                                                    design and weight other than those              (a)        Cylinder   of   any   size, 
                                                    specified in Schedule 'A'  conforming           shape, design and weight other than 
                                                    to   Indian   Standard   specifications,        those   specified   in   Schedule   'II' 
                                                    without   however   any   restriction   on      conforming   to   Indian   Standard 






HC-NIC                                                        Page 28 of 41           Created On Fri Oct 14 00:46:36 IST 2016



               LPG (RSD) ORDER, 1988          LPG (RSD) ORDER, 1993                          LPG (RSD) ORDER, 2000
                                       water capacity.                                Specifications.
                                       (b) Gas cylinder valve conforming to           (b)          Gas   cylinder   valve 
                                       IS   specification   8737,   Part II           conforming to IS specification 8737 , 
                                       specification   but   the   outer   collar     Part II  of any size having an outlet 
                                       diameter   size   should   be   different      collar dia. of 22.0mm.
                                       than 25.6 mm.                                  (c)          Pressure               regulator 
                                       (c) Pressure regulators conforming to          conforming  to IS  specification  9798 
                                       Indian   Standard   specification   9798       of any size and having an inlet dia. 
                                       of   any   size   and   having   an   inlet    other than of 22.0mm.
                                       diameter other than of 25.6 mm.                NOTE:
                                                                                      1.           The   cylinder   used   by   a 
                                                                                      parallel marketeer shall be provided 
                                                                                      with a valve protection ring different 
                                                                                      in   shape   from   that   in   the   cylinder 
                                                                                      used by a Government Oil Company.
                                                                                      2.           The   cylinder   used   by   a 
                                                                                      parallel   marketeer   shall   be   clearly 
                                                                                      marked with Colour Band and Logo 
                                                                                      of their respective company, firm or 
                                                                                      person   marketing   liquefied 
                                                                                      petroleum   gas,   as   approved   by   the 
                                                                                      Chief Controller of Explosives.
                                                                                      3.           Maximum   permissible 
                                                                                      error   on   net   quantities   declared   by 
                                                                                      weight   or   by   volume   shall   be   as 
                                                                                      below:...........




         5.2      Referring   the   above   chart,   the  learned   advocate   for   the 

                  appellants has mainly submitted as under: