Meter terminal seal, meter half seals and hologram seals of
single phase electronic installed at the premises were found
tampered.
b) Meter was segregated ... performing the accuracy check with standard accu
check instrument meter was found 79.69 % slow.
Consumer did not allow the inspection team to proceed
further. Notice
meter was checked.
The meter terminal seals were found intact. The accuracy of the meter
was checked with accucheck instrument. The meter was found slow ... three phase whole current electronic meter was installed in the name
of accused no.2. The meter was checked. The meter was not showing
phases
that
meter terminal seals, meter half seals, ultrasonic welding hologram seal of the
meter were found tampered with. On performing accuracy check, meter ... there were three
meters and 1 submeter in the same meter box. Witnesses was also unable to
explain that the meter was under
following irregularities:
"Both half seal of the meter found missing.
Meter body found tampered. Accucheck
result = 58.19% (slow). There are other
meter (Meter ... Some other
tangible evidence must been shown to
exist. An accu check meter can be deployed
to find out if the meter is in fact
checked. Meter box, meter
terminal and meter half seals were found refixed. The meter was
found slow by 29.84 % as checked with accucheck ... site. The calibration
certificate of accucheck is carried before checking with accucheck.
The accucheck is presumed to be correct in terms
premises and noted down the working of
existing meter and found that meter was checked on each phase
and on external hearing load ... period the meter was not in working
condition till the meter is replaced and to refund the excess meter, if
any, recovered from the complainant
change over switch or not. He admitted that he had
not checked the meter installed in the premises and volunteered
because of the crowd ... recording less than the units actually,
passing through it. A check meter affords an easy
method of proving the consumer's meter is recording
torch which the accused Rajesh was carrying at the time of checking
the meter as a Meter Reader which torch is Ex.P1; monkey ... when somebody
from outside told her that they had come to check the meter but she did
not open the door when they asked
Kumar
Khanna allowed them to enter his house and also to check electricity
meter installed in his house.
20.Ld. Defence Counsel argued on behalf ... Kumar Khanna
allowed them to enter his house and to check the electricity meter. He
would not have allowed them
meter box plastic
and hologram seals were tampered and re- fixed. The meter half
seals and meter terminal seals of the meter were tampered ... meter of the consumer was tampered as meter box seals, meter
terminal seals, meter half seals, meter ultrasonic seal were tampered
and the meter