(2)Space requirement of different component of a building. - Minimum size, width and height of different components of building(s), low/high rise as given below in Table 34 and Table 35, namely:-
Table 34:Minimum requirements of different component of a building
S.No. Components of building Minimum requirement
    Area(sq.m) Width (m) Clear Height (m)
I. Habitable room 9.5 2.4 2.75
II. kitchen:where separatediningarea is providedwhere there isseparate store is providewhere dinning included 5.04.57.5 1.81.82.1 2.75
III. Bathroom 1.8 1.2 2.1
IV. water closet(w.c) 1.2 0.9 2.1
V. combined bath and w.c 2.8 1.2 2.1
VI. Store 3.0 1.2 2.2
VII. Garage 18 3.00 2.4
VIII. Single occupancy Hostel Room 7.5 2.1 2.75
IX. Single occupancy Servant Room 7.5 2.1 2.75
Note. - (a) Where two rooms are attached, one of these shall not be less than 9.5 sq.m and the other not less than 7.5 sq.m with a minimum width of 2.1 m.
(b)In the case of pitched roof, the average height of rooms shall not be less than 2.75 m. The minimum clear head room under a beam, folded plates or eaves shall be 2.4 m.
(c)In the case of air-conditioned rooms, a height of not less than 2.4 m measured from the surface of the floor to the lowest point of air conditioning duct or the false ceiling shall be provided:
Provided that the requirements of above table shall apply to residential, business and mercantile buildings. For educational and industrial buildings, the minimum requirements are mentioned in table below:
Table 35: Minimum height requirement foreducational and industrial buildings
S.No. Type of building Minimum Ceiling Height
I. Educational building 3.6 m
II. Industrial Buildings 3.6 m, except when air-conditioned where it is3m
III. Religious Building 3.6 m