Section 3 in Fees Payable For The Services Of Electrical Inspectors Or Any Officer Appointed To Assist The Electrical Inspectors
3. Payment of fees.
| Capacityof each motor | Fees(Rs.) |
| (i)Up to and including 5 HP | 30.00 |
| (it)Exceeding 5 HP and up to and including 10 HP | 45.00 |
| (iii)Exceeding 10 HP and up to and including 25 HP | 150.00 |
| (iv)Exceeding 25 HP and up to and including 50 HP | 250.00 |
| (v)Exceeding 50 HP and up to and including 100 HP | 400.00 |
| (vi)Exceeding 100 HP | 500.00 |
| (a)For each generating unit along with mountings on the generatorthe fees shall be as follows. | |
| Capacityof generating unit installed in KW | Fees(Rs.) |
| (i)Up to and including 25 KW | 250.00 |
| (ii)Exceeding 25 KW but not exceeding 100 KW | 750.00 |
| (iii)Exceeding 100 KW but not exceeding 500 KW | 1,500.00 |
| (iv)Exceeding 500 KW but not exceeding 1,000 KW | 2,500.00 |
| (v)Exceeding 1, 000 KW but not exceeding 10,000 KW | 5,000.00 |
| (vi)Exceeding 10,000 KW but not exceeding 50,000 KW | 7,500.00 |
| (vii)Exceeding 50,000 KW but not exceeding 2,00,000 KW | 10,000.00 |
| (viii)Exceeding 2,00,000 KW but not exceeding 5,00,000 KW | 15,000.00 |
| (ix)For each additional 1,00,000 KW or part thereof | 5,000.00 |
| Note.- If the excitor is grounded separately then separate feeshall be payable and the same shall be as for a motorinstallation. | |
| (b)Bus ducts or cables or both connecting generation unit to theswitchgear : | |
| (i)For EHV/HY | Rs.250.00 |
| (ii)For MV | Rs.100.00 |
| (c)The control panel of each generating unit- | |
| (i)For EHV/HV | Rs.250.00 |
| (ii)For MV | Rs.100.00 |
| (d)Each motor installation for controlling auxiliaries along withits control gear. | |
| Asper Scale `A' | |
| (e)One block of distribution panels with continuous bus- | |
| (i)For EHV/HV | Rs.250.00 |
| (ii)ForMV | Rs.100.00 |
| (f)Cables connecting the power house to the switchgear or theoverhead line as the case may be | |
| (i)For EHV/HV | Rs.250.00 |
| (ii)For MV | Rs.100.00 |
| (g)Each transformer in a power station either in station service orin distribution whether step-up or step-down. As per Scale `C-2' | |
| (h)Outgoing cable from a transformer to the switchgear | |
| (i)For EHV/HV | Rs.250.00 |
| (ii)For MV | Rs.100.00 |
| (i)Outdoor switchyard. As per Scale `C' | |
| (j)G.O. switches and the connecting bus links in case of a smalloutdoor transformer installation in generating station. | Rs.100.00 |
| (a) For eachtransformer in a grid sub-station or outdoor switch yard, thescale of fee shall be as given in the following Table : | |
| Capacityof each transformer unit | Fees(Rs.) |
| (i) Upto andincluding 100 KVA | 250.00 |
| (ii) Exceeding 100KVA but not exceeding 500 KVA | 500.00 |
| (iii) Exceeding500 KVA but not exceeding 1000 KVA | 1,000.00 |
| (iv) Exceeding1000 KVA but not exceeding 5000 KVA | 1,500.00 |
| (v) Exceeding 5000KVA but not exceeding 10,000 KVA | 2,500.00 |
| (vi) Exceeding10,000 KVA but not exceeding 20,000 KVA | 3,750.00 |
| (vii) For eachAddl. 10,000 KVA or part thereof | 500.00 |
| (b) Each block orpanels in control room or the grid sub-station per cubicle | Rs.50.00 |
| (c) The batteryroom installation like rectified battery charges per battery room | Rs.500.00 |
| (d) One block ofMV distribution panels or switches | Rs.250.00 |
| (e) Synchronouscondensors | as perTable above |
| (f) One bank ofcapacitors | Rs.500.00 |
| (g) Each motorrunning a machine | As perScale 'A ' |
| (h) Each set oflightning arrestors, CTs, PTs, CVTs and coupling capacitors foreach set | Rs.250.00 |
| (i) Each set ofbuses inclusive of its isolators | Rs.250.00 per set |
| (j) Each set ofEHV isolators | |
| (c) For 220 KV andabove | Rs.500.00 per set |
| (ii) For below 220KV | Rs.250.00 per set |
| (k) Each set ofOCBs along with its associated equipment | |
| (i) For EHV | Rs.1000.00 |
| (ii) For HV | Rs.500.00 |
| (a) Incoming polestructure having no transformer but including GO switches, dropout fuses and lightning arrestors | |
| (i) Fee for mediumvoltage | Rs.275.00 |
| (ii) Fee for highvoltage up to and including 11 KV | Rs.500.00 |
| (iii) Fee for highvoltage exceeding 11 KV | Rs.1000.00 |
| (b) Thetransformer in the sub-stations | as perScale C (by) |
| (c) One block ofcontrol panels with circuit breakers and with continuous buspanel. | Rs.50.00 per panel |
| (d) HT cablesconnecting the pole structure with the transformer | Rs.250.00 |
| (e) In case ofindoor sub-station cable from the pole structure to the controlpanels. | Rs.250.00 |
| (f) A set ofcontrol panels | Rs250.00 |
| (g) Cables goingfrom the control panels to the transformer | Rs.250.00 |
| (h) Eachdistribution box controlling more than one feeder | Rs.100.00 per box |
| (i) Cables from MVswitchboard to the outgoing overhead line per cable | Rs.50.00 |
| (a)For the initial inspection, examination or testing of anyelectric installation, appliance or apparatus in a cinema or atheatre other than a travelling cinema or other temporary placeof public entertainment referred to in CI. (d) | Rs.1000.00 |
| (b)For every subsequent inspection, examination or testing of theinstallation, appliance or apparatus, in cinemas or theatresreferred to in Cl. (a) | Rs.500.00 |
| (c)For an inspection, examination or testing of an authorisedaddition or alteration to the electric installation in cinema ora theatre referred to in Cl. (a) | Rs.100.00 |
| (d)(i) For an inspection, examination or testing of any electricinstallation, appliance or apparatus in a travelling cinema orother temporary place of public entertainment. | Rs.500.00 |
| (ii)For every subsequent inspection, examination or testing of anyelectric installation, appliance or apparatus in such cinema orplace of public entertainment periodical or necessitated onaccount of change of place or premises. | Rs.250.00 |
| (e)For an inspection, examination on testing of electricinstallation, appliance or apparatus in a travelling ortemporary cinema or other temporary place of public entertainmentnecessitated on account of a change of installation, applianceor apparatus so as to conform to the rules and regulations forpermanent places of public amusement. | Rs.500.00 |
| (a) For lightningor purposes other than power provided that no fees under thisitem shall be charged in respect of electrical installation,appliance or apparatus in any factory which does not come underthe purview of the Factories Act, 1948 (63 of 1948). | Rs.50.00/KW of connected load or part thereofsubjectto a max. of Rs. 500.00 |
| (Provided thateach separate building or shed in a factory or workshop withinthe factory premises shall be treated as one unit for determiningthe connected load) | |
| (b) For each motorwith starter as per Scale `A' | |
| (c) Distributionsystem for supplying power to more than one motor | Rs. 50/ |
| (d) For generatingstations, grid sub-stations or distribution sub-station in whichenergy is or is about to be generated or transformed ordistributed. | As perScale 'B' to 'D' |
| (e) For overheadtraveling cranes: | |
| (i) Mainswitchboard, rails and cabins | Rs.500.00 |
| (ii) Motor Unit | As perScale 'A' |
| (a) EHV powersupply to consumers: | |
| For inspection ofpower supply lines to the EHV consumers and the sub-stations, thefee to be charged shall be as per Scale'I' and Scale `C' as maybe applicable. | |
| (b) Power supplyto HV consumers: | |
| The incomingstructure to be charged as per scale laid down under Scale `D'and if the sub-section is to be put up at the consumer'spremises, the fees shall be as per Scale `C'. The charge forinspection fee for lines cables shall be as laid down in Scale`I'. | |
| (c) Power supplyto MV consumers: | |
| For medium voltageor low voltage service connection | Rs. 30/ |
| (d) Multi-storeyedbuildings : | |
| (i) fee for eachMV distribution board | Rs. 30/ |
| (ii)lightning/fan/load connected load or part thereof. | Rs. 30/per KW |
| (iii) in case oflifts, the fee to be levied shall be as follows: | |
| Controllingpanels/boards | Rs.150/ |
| Motor Unit | As perScale 'A' |
| (e) All IndiaRadio/Doordarshan: | |
| In case ofAIR/Doordarshan, the fee to be levied shall be as follows: | |
| (i) eachtransmitter panel | Rs.500/ per panel |
| (ii) receivingstation | Rs.250/ (mini.) |
| (f) X-ray Plants: | |
| Fee to be leviedon inspection of X-ray plants shall be as follows: | |
| (i) First 10 KVA | Rs. 90/ |
| (u) for each KVAin excess thereof | Rs. 15/ |
| (g) Neon-signs | |
| The fee to belevied for inspection of neon-signs shall be | MinimumRs. 150/ up to 400 KVA Rs. 15/ per each KVA or part thereof inexcess |
| (a) each tower inan EHV line (66 KV and above) | Rs.250/ per tower |
| (b) each crossing,road crossing, crossing over P & T lines and other powerlines, river crossing or crossing over buildings. | (i)EHV/HV line Rs. 250/ per crossing |
| (ii) MVline Rs. 50/ per crossing |
| (a) (1) EHV aeriallines or cables (above 33KV) | Rs.250/ per 5 kms of circuit length or part thereof |
| (ii) For HV aeriallines or cables at voltage below 33 KV | Rs.150/ per 5 kms of circuit length or part thereof |
| (iii) Overheadaerial lines or cables of medium and low voltage. | Rs.100/ per 5 kms of circuit length or part thereof |
| (b) Tee off point,transposition and sectionalising points : | (i)HV-Rs. 100/ per point(ii)MV-Rs. 50/ per point |
| (c) Booster andcapacitors banks : | Rs.100/ |
| Forinspection or issue of certificate under sub-rule (3) of rule 82of the Indian Electricity Rules, 1956. | Rs.250/ |
| Foran inspection or examination of any electric traction systemincluding trolley wires and overhead equipment and test ofbonding and leakage current | Rs.500/ a day or part thereof |
| (i)Up to and including a capacity of 50 Amps : | |
| -for low pressure installations | Rs.75/ |
| -for medium pressure installations | Rs.100/ |
| -for high pressure installations | Rs.125/ |
| (ii)for a capacity exceeding 50 Amps but not exceeding 200 Amps : | |
| -for low pressure installations | Rs.100/ |
| -for medium pressure installations | Rs.125/ |
| -for high pressure installations | Rs.150/ |
| (iii)For a capacity exceeding 200 Amps : | |
| -for low pressure installations | Rs.175/ |
| -for medium pressure installations | Rs.200/ |
| -for high pressure installations | Rs.250/ |
| Forinspection and testing of any main, distribution mains orservice line internal wiring of medium and high voltage for thediscovery of leakage therein which may result in electrolysis orinjury to any water, gas or other pipe or any applianceconnected therewith. | Rs.200/ for the first hour or part thereof.Rs.100/ for next hour or part thereof |
| -If any leakage, is discovered in any such main distributing main,or service line, the fee shall be paid by the licensee or theowner of the main, distributing main or service lines as thecase may be. | |
| -Ifno leakage is discovered, the fee shall be paid by the owner ofthe water, gas or other pipe or of the appliance connectedtherewith. |
| (a)For the testing of an installation for leakage to earth | Rs.50/- |
| -The fee shall be paid by the party making such application. |
| (a)For locating of leakage to earth in any installation | Rs.50/ for first hour or part thereof.Rs.25/ for next hour or part thereof. |
| (a)For deciding any case of difference or dispute arising underSec. 41(4), 26(4) or 26(6) of or Cl. V(2) or VI(3) of theSchedule to the Indian Electricity Act, 1910 (9 of 1910) referredto the Inspector. | Rs.250/ per decision |
| (b)The fee shall be paid in advance by the party referring thedispute, but will be borne finally by the person against whomthe decision is given : | |
| Providedthat in the case of difference or dispute referred to theElectrical Inspector for being decided under Sec. 26(6) of thesaid Act, an additional fee for the testing of a meter inaccordance with Scale 'L' shall be recoverable. | |
| (c)The fee shall be chargeable in respect of each hearing and eachinspection necessitated in this connection. |