23. Institutional.

- The institutional buildings shall be governed by the following norms, namely:-
Table 24: Hospital, Nursing Home, MedicalLaboratory
S. No. Parameter Permissible Limits  
I. Minimum Approach Road and Site Area Plot size from 1000 sq.yd upto 2000 sq.yd 12m (40'-0")
Plot size above 2000 sq.yd upto 4000 sq.yd 18m (60'-0")
Plot size above 4000 sq.yd 24m (80'-0")
II. Maximum Ground Coverage 40% of site area  
III. Maximum Floor Area Ratio Minimum approach road 12 m 1:1.50
Minimum approach road 18 m 1:1.75
Minimum approach road 24 m and above 1:2.25
IV. Maximum Height of Building No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms.
V. Parking 2[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).].
VI. Setbacks around buildings Refer sub-rule (1) of rule 26 of these buildingrules.
Notes. - (a) Maximum up to 2% of covered area shall be allowed to be used for community space / crèche / chemist shop/ bank counter on Hospital sites and also Medical College/ Nursing and Paramedic institutes sites.
(b)In case of Hospitals, 25% of the total covered area (Floor Area Ratio) may be utilized for residential use for staff, dormitory/ hostels for attendants of the patients, crèche etc.
(c)Adequate arrangements for disposal of hospital waste have to be made as per the Bio- Medical Waste (Management and Handling) Rules, 1998, as amended from time to time along with the instructions/ guidelines issued by the Punjab Pollution Control Board from time to time.
(d)F.A.R above 1:1.50 will be chargeable on pro-rata basis. However the site allotted or sold by the development authority the charges shall be applicable as per the terms and conditions of the allotment letter.
Table 25: Orphanage Home, Old Age Home,Children's Centre/Care Centre/School/ Institute for Mentallychallenged or Physically Handicapped Person
S. No. Parameter Permissible Limits
I. Minimum Site area 1000 sq.m
II. Minimum Approach Road 12m(40'-0")
III. Maximum Ground Coverage 50%
IV. Maximum Floor Area Ratio 1:1.5
V. Maximum Height of Building No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms.
VI. Parking 1.0[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).].
VII. Setbacks around buildings Refer sub-rule (1) of rule 26 of these buildingrules.
Notes. - (a) Minimum 15% of site area shall be kept/developed as playground/green with minimum width of 15 m.
(b)In case of school for mentally/differently able persons, 25% of the total covered area (Floor Area Ratio) can be utilized for residential use for essential staff and student accommodations.
(c)In case of Hospitals, 25% of the total covered area (Floor Area Ratio) may be utilized for residential use for staff, dormitory/ hostels for attendants of the patients, crèche etc.
(d)Adequate arrangements for disposal of hospital waste have to be made as per the Bio- Medical Waste (Management and Handling) Rules, 1998, as amended from time to time along with the instructions/guidelines issued by the Punjab Pollution Control Board from time to time.