Legal Document View

Unlock Advanced Research with PRISMAI

- Know your Kanoon - Doc Gen Hub - Counter Argument - Case Predict AI - Talk with IK Doc - ...
Upgrade to Premium
[Cites 0, Cited by 0] [Section 55] [Entire Act]

State of Bihar - Subsection

Section 55(7) in Bihar Factories Rules, 1950

(7)Gill Boxes. - (a) The feed shall be guarded so as to prevent fingers being caught in the pins of the intersecting fallers.
(b)All nips of in-running rolls shall be guarded by suitable nip guards conforming to the following specifications.
Note. - Any opening which the guard may permit when fitted in position shall be so restricted with respect to the distance of the opening from any nip point that the fingers of any person shall not reach that point through that opening and in any circumstances, the maximum width of the opening shall not exceed the following :
Distance of opening from nip point   Maximum width of opening
0 to 38 mm. - 6 mm.
39 to 63 mm. - 10 mm.
64 to 88 mm. - 13 mm.
89 to 140 mm. - 15 mm.
141 to 165 mm. - 19 mm.
166 to 190 mm. - 22 mm.
191 to 215 mm. - 32 mm.