[Cites 0, Cited by 0]
[Entire Act]
State of Punjab - Section
Section 22 in Punjab Urban Planning and Development Building Rules, 2018
22. (A) Educational.
- The educational buildings shall be governed by the following norms, namely:-| Table 21: Pre Nursery / Nursery School /crèche | |||
| S.No. | Parameter | Permissible Limits | |
| I. | Minimum Site area | 1000 sq.m | |
| II. | Minimum Approach Road | 12 m | |
| III. | Maximum Ground Coverage | 40% of site area | |
| IV. | Maximum Floor Area Ratio | 1:1.0 | |
| V. | Setbacks around buildings | Front | 6m or 1/3 of the height of the building,whichever is more |
| Other side | 4.5m or 1/3 of the height of the building,whichever is more | ||
| VI. | Parking | 1.5[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).] | |
| VII. | Maximum number of Floors | G+1 |
| Table 22: Primary school (class 1 to 5) | ||
| S. No. | Parameter | Permissible Limits |
| I. | Minimum Site area | As per the norms of the affiliation authorityor 5000 sq mts whichever is more |
| II. | Minimum Approach Road | 12m |
| III. | Maximum Ground Coverage | 40% of site area |
| IV. | Maximum Floor Area Ratio | 1:1.2 |
| V. | Parking | 1.5[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).] |
| VI. | Maximum Height of Building | below 15m |
| VII. | Setbacks around buildings | Refersub-rule (1) of rule 26of thesebuilding rules. |
| Table 23: High/ Senior secondary school/College or Educational Institute/Universities. | |||
| S. No. | Parameter | Permissible Limits | |
| I. | Minimum Approach Road | for School | Within Master Plan-18m (60'-0")Outside Master Plan-12m (40'-0") |
| for College/university | Within Master Plan-24m (80'-0")Outside Master Plan-18m (60'-0") | ||
| II. | Maximum Ground Coverage | 40% of plot area | |
| III. | Maximum Floor Area Ratio | 1:1.5 | |
| IV. | Parking | School, College | 1.5[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).]. |
| University Campus | 1.0[Equivalent Car Space per 100 square meters of the total Floor Area Ratio] [Substituted 'Equivalent Car Space per 100 square meters of the total covered area' by Notification No. G.S.R.33/P.A.11/1995/Ss.43 and 180/Amd. (3)/2019, dated 04.10.2019 (w.e.f. 12.6.2018).]. | ||
| V. | Maximum Height of Building | No Restriction subject to clearance from AirportAuthority and fulfilment of norms such as setbacks aroundbuilding, ground coverage, F.A.R., structural safety and firesafety norms. | |
| VI. | Setbacks around buildings | Refersub-rule (1) of rule 26of thesebuilding rules. |