Section 45 in Kerala Municipality Building Rules, 1999
45. Exit Width.
| Sl. No. | Group of occupancy | No. of Occupants per unit exit width ofStairway | Doors |
| (1) | (2) | (3) | (4) |
| 1. | Group A1 Residential | 25 | 75 |
| 2. | Group A2 Special Residential | 50 | 75 |
| 3. | Group B Educational | 25 | 75 |
| 4. | Group C Medical/Hospital | 25 | 75 |
| 5. | Group D Assembly | 60 | 90 |
| 6. | Group E | 50 | 75 |
| 7. | Group F Mercantile (Commercial) | 50 | 75 |
| 8. | Group G1 Industrial | 50 | 75 |
| 9. | Group G2 Small Industrial | 50 | 75 |
| 10. | Group H Storage (including Warehousing) | 50 | 75 |
| 11. | Group I Hazardous | 25 | 40 |
| Sl. No. | Group of occupancy | Occupant Load (gross area in square meters perperson) |
| (1) | (2) | (3) |
| 1. | Group A1 Residential | 12.5 |
| 2. | Group A2 Special Residential | 4.0 |
| 3. | Group B Educational | 4.0 |
| 4. | Group C Medical/Hospital | 15.0 |
| 5. | Group D Assembly | 1.5 |
| 6. | Group E Office | 1.5 |
| 7. | Group F Mercantile (Commercial) | 3 to 6 |
| 8. | Group G1 Industrial | 10.0 |
| 9. | Group G2 Small Industrial | 10.0 |
| 10. | Group H Storage (including Warehousing) | 30.0 |
| 11. | Group I Hazardous | 10.0 |