State of Punjab - Subsection

Section 30(21) in Punjab Urban Planning and Development Building Rules, 2018

(21)Fitments for drainage and sanitation. - (i) For Residences. - Dwelling with individual convenience shall have at least the following fitments, namely:-
(a)One bath room provided with a tap and a floor trap;
(b)One water closet with flushing apparatus with an ablution tap / health faucet; and
(c)One tap with a floor trap or a sink in kitchen.
(ii)The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Table 36 to Table 49.
Table 36: Office Building
S.No. Fixtures Public Toilets Staff Toilets
    Male Female Male Female
Executive Rooms and Conference Halls inOffice Buildings
I. Toilet suite comprising one Water Closets (WC), onewash basin (with optional shower stall if building is used roundthe clock at user's option) Pantry optional as per userrequirement Unit could be common for male/female or separate depending on thenumber of user of each facility For individual officer rooms
Main Office Toilets for Staff and Visitors
II. Water Closets (WC)     1 per 25 1 per 15
III. Ablution tab with each water closet   1 in each water closet
IV. Urinals see note see note Nil up to 61 for 7 to 202 for 21 to 453 for 46 to 704 for 71 to 100From 101 to 200,add @3%;for over 200, add @ 2.5% -
V. Wash Basins 25 25
VI. Drinking Water Fountain 1 per 100 persons    
VII. Cleaner's sink 1 per floor    
Note. - Staff and public toilet utilities are generally common in office buildings. Where public toilets are to be provided separately, similar requirements as that of staff toilet may be provided.
Table 37:Cinema, Multiplex Cinema, Concert and Convention Halls, Theatresand Stadia
S. No. Fixtures Public Toilets Staff Toilets
Male Female Male Female
I. Water Closets 1 per 100 upto 400;Over 400 add at 1 per 250 or part thereof 3 per 100 upto 200;Over 200 add at 2 per 100 or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals 1 per 25 or part thereof - 1 for 1 to 202 for 21 to 45 -
IV. Wash Basins 1 per 200 or part thereof 1 for upto 152 for 16 to 35 1 for upto 122 for 13 to 25
V. Drinking Water Fountain 1 per 100      
VI. Cleaner's sink 1 per floor      
VII. Showers/bathing rooms As per trade requirements    
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as one-third.
Table 38: ArtGalleries, Libraries and Museums
S. No. Fixtures Public Toilets Staff Toilets
Male Female Male Female
I. Water Closets 1 per 100 upto 400;Over 400 add at 1 per 250 or part thereof 3 per 100 upto 200;Over 200 add at 2 per 150 or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals 1 per 25 or part thereof - 1 for 1 to 202 for 21 to 45 -
IV. Wash Basins 1 per 100 upto 400;Over 400 add at 1 per 250 or part thereof 3 per 100 upto 200;Over 200 add at 2 per 150 or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
V. Drinking Water Fountain 1 per 100      
VI. Cleaner's sink 1 per floor      
VII. Showers/bathing rooms As per trade requirements    
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as one-third.
Table 39: Restaurants
S. No. Fixtures Public Toilets   Staff Toilets  
Male Female Male Female
I. Water Closets 1 per 50 seats up to200;Over 200 add at 1 per 100 or part thereof 2 per 50 seats up to 200;Over200 add at 1 per 100 or part thereof 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals 1 per 50 persons or part thereof - 1 for 1 to 202 for 21 to 453 for 46 to 654 for 66 to 100 -
IV. Wash Basins 1 per Water Closets (WC) 1 per Water Closets (WC) 1 per Water Closets (WC) 1 per Water Closets (WC)
V. Cleaner's sink 1 per restaurant      
VI. Kitchen sink/dish washer 1 per kitchen      
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as one-third.
(c)Provision for additional and special fittings where required shall be made.
Table 40: Shopping Malls and Retail Buildings
S.No. Fixtures Public Toilets for floating population Staff Toilets in Shopping Building
Male Female Male Female
I. Water Closets 1 per 50 (min. 2) 1 per 50 (min. 2) 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100
II. Ablution tab 1 in each water closet
III. Urinals 1 per 50 - 1 for 1 to 202 for 21 to 453 for 46 to 654 for 66 to 100 -
IV. Wash Basins 1 per Water Closets (WC) 1per Water Closets (WC) 1per Water Closets (WC) 1per Water Closets (WC)
V. Cleaner's sink 1 per floor      
VI. Bath/showers 1 per 100 persons      
Notes. - (a) Toilet facilities for individual facilities in a shopping building should be taken same as that for office buildings.
(b)Staff toilets in the shopping buildings provide facilities for persons working in shops and building, as well as for maintenance staff.
(c)The number of persons against the fixture bath/showers represent the maintenance staff requiring such facility.
(d)Public toilet facilities are provided for a large floating population for buyers and visitors.
(e)Some Water Closets (WC) may be Indian style, if desired.
(f)Male population may be assumed as two-third and female population as one-third.
(g)Provision for additional and special fittings where required shall be made.
Table 41:Hotel
S. No. Fixtures Public Room Non Residential Staff
Male Female Male Female
I. Toilet suite comprising one Water Closets (WC),wash basin with shower or a bath tub Individual guest rooms with attached toilets -  
Guest room with common facilities
II. Water Closets 1 per 100 persons upto400;over 400 add at 1 per 250 or part thereof 1 per 100 persons upto200;over 200 add at 1 per 100 or part thereof 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100
III. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
IV. Urinals 1 per 50 person or part thereof - 1 for 1 to 202 for 21 to 453 for 46 to 654 for 66 to 100 -
V. Wash Basins 1 per Water Closets (WC) 1 per Water Closets(WC)2 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 152 for 13 to 253 for 26 to 404 for 41 to 57 1 for up to 12
VI. Bath (showers) 1 per 10 person or part thereof      
VII. Cleaner's sink 1 per 30 rooms, minimum 1 per floor      
VIII. Kitchen sink 1 per kitchen      
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as onethird.
(c)Provision for additional and special fittings where required shall be made.
Table 42: Hospital with indoor patient ward
S. No. Fixtures Public Toilets Staff Toilets
Male Female Male Female
I. Toilet suite comprising one Water Closets (WC),one wash basin and shower stall Private room with up to 4 patient For individual doctor's/officer's rooms
For General wards, Hospital staff and visitors
II. Water Closets 1 per 5 Beds or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
III. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
IV. Urinals 1 per 15 beds - 1 for 1 to 202 for 21 to 45 -
V. Wash Basins 2 for every 30 bedsor part thereof.Add 1 per additional 30 beds or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
VI. Drinking Water Fountain 1 per Ward 1 per 100 person or part thereof
VII. Cleaner's sink 1 per Ward -  
VIII. Bed pan sink 1 per Ward 1 per Ward -  
IX. Kitchen sink 1 per Ward 1 per Ward -  
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as onethird.
(c)Provision for additional and special fittings where required shall be made
(d)Drinking water fountain are not recommended for hospitals for reasons of infection control. This is to be decided by the health authority recommendations.
Table 43: Hospital with Outdoor PatientDepartment
S. No. Fixtures Patient Toilets   Staff Toilets  
Male Female Male Female
I. Toilet suite comprising one Water Closets (WC) andone wash basin (with optional shower stall if building used for24 h) For up to 4 patient   For individual doctor's/officer's rooms
II. Water Closets 1 per 100 persons or part thereof 2per 100 persons or part thereof 1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
III. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
IV. Urinals 1 per 50 persons or part thereof - 1 for 1 to 202 for 21 to 45 -
V. Wash Basins 2 per 100 persons or part thereof   1 for up to 152 for 16 to 35 1 for up to 122 for 13 to 25
VI. Drinking Water Fountain See note (d)   1 per 100 person or part thereof
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as onethird.
(c)Provision for additional and special hospital fittings where required shall be made.
(d)Drinking water fountain are not recommended for hospitals for reasons of infection control. This is to be decided by the health authority recommendations.
(e)The Water Closets (WC) shall be provided keeping in view the location of main Out Patient Department (OPD) waiting hall and sub-waiting halls, floor wise, so as to serve the people effectively. The number of patients shall be calculated floor wise. The Out Patient Department (OPD) population shall include patient attendants @ at least 1 per patient.
Table 44:Hospital Administrative Buildings
S. No. Fixtures Staff Toilets  
    Male Female
I. Toilet suite comprising one Water Closets (WC) andone wash basin (with optional shower stall if building used for24 h) For individual doctor's /officer's rooms
II. Water Closets 1 per 25 persons or part thereof 1 per 15 persons or part thereof
III. Ablution tab 1 in each water closet1 water tap with draining arrangements shall be provided forevery 50 persons or part thereof in the vicinity of water closetsand urinals
IV. Urinals Nil up to 61 for 6 to 152 for 16 to 50 -
V. Wash Basin 1 per 25 persons or part thereof
VI. Drinking Water Fountain 1 per 100 persons or part thereof( see note c)
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as two-third and female population as one-third.
(c)Drinking water fountains to be provided only where it is a separate block and patients will not use it.
Table 45: Factories
S No. Fixtures Offices/Visitors Workers  
Male Female Male Female
I. Water (workers and staff) Closets 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100From 101 to 200, add @ 3%;for over 200, add @ 2.5% 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100From 101 to 200, add @ 5%;for over 200, add @ 4% 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100From 101 to 200, add @ 3%;for over 200, add @ 2.5% 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100From 101 to 200, add @ 5%;for over 200, add @ 4%
II. Ablution tab 1 in each water closet
III. Urinals 1 for 1 to 202 for 21 to 453 for 46 to 704 for 71 to 100From 101 to 200, add @ 3%;for over 200, add @ 2.5% - 1 for 1 to 202 for 21 to 453 for 46 to 704 for 71 to 100From 101 to 200, add @ 3%;for over 200, add @ 2.5% -
IV. Wash Basins(wash basins in rows or troughs and tapsspaced 750 mm c/c) 1 per 25 or part thereof    
V. Drinking Water Fountain 1 per 100 persons or part thereof with minimumone on each floor
VI. Cleaner's sink 1 on each floor      
VII. Showers/bathing rooms As per trade requirements    
VIII. Emergency shower and eye wash fountain - - 1 per every shop floor per 500 persons
Notes. - (a) For factories requiring workers to be engaged in dirty and dangerous operations or requiring them to being extremely clean and sanitized conditions, additional and separate (if required so) toilet facilities and if required by applicable Industrial and safety laws and the Factories Act shall be provided in consultation with the user.
(b)Depending on the type of disability of a person and the hazard posed by the type of activities in the factory for a person with disabilities, if a person with disabilities is decided to be engaged for a particular activity, the requirements of accessibility shall be guided by the provisions given in 13 of Part 3 -'Development Control Rules and General Building Requirements of the National Building Code of India, 2016'.
Table 46: Schools and EducationalInstitutions
S No. Fixtures Nursery School Non-Residential Residential
Boys Girls Boys Girls
I. Water Closets 1 per 15 pupils or part thereof 1 per 40 pupils or part thereof 1 per 25 pupils or part thereof 1 per 8 pupils or part thereof 1 per 6 pupils or part thereof
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals - 1 per 20 pupils or part thereof - 1 per 25 pupils or part thereof -
IV. Wash Basins 1 per 15 pupils or part thereof 1 per 60 pupils or part thereof 1 per 40 pupils or part thereof 1 per 8 pupils or part thereof 1 per 6 pupils or part thereof
V. Drinking Water Fountain 1 per 50 pupils or part thereof 1 per 50 pupils or part thereof 1 per 50 pupils or part thereof
VI. Cleaner's sink 1 per each floor  
VII. Bath / Showers 1 per 40 pupils or part thereof -   1per 8 pupils or part thereof 1per 6 pupils or part thereof
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building.
Table 47: Hostels
S No. Fixtures Resident Non-Resident Visitor/Common Room
Males Females Males Females Males Females
I. Water Closets 1 per 8 or part thereof 1 per 6 or part thereof 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776 for 78 to 100 1 per 100 upto 400;over 400 add at 1 per 250 1 per 100 upto 200;over 200 add at 1 per 100
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals 1 per 25 or part thereof - 1 for 1 to 202 for 21 to 453 for 46 to 704 for 71 to 100 - 1 per 50 or part thereof -
IV. Wash Basins 1 per 8 or part thereof 1 per 6 or part thereof 1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 1005 for 58 to 776 for 78 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 57 1 per water Closets(WC) 1 per water Closets(WC)
V. Bath/showers 1 per 8 or part thereof 1 per 6 or part thereof - - - -
VI. Cleaner's sink 1 per each floor          
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
Table 48: Fruit and Vegetable Markets
S No. Fixtures Shop Owners Common toilets in market building Public toilet for floating population
Males Females Males Females Males Females
I. Water Closets 1per 8 or part thereof   1 for up to 152 for 16 to 353 for 36 to 654for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 575 for 58 to 776for 78 to 100 1 per 50 (min 2) 1 per 50 (min 2)
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals - - 1 for 1 to 202 for 21 to 453 for 46 to 704 for 71 to 100 - 1 per 50 -
IV. Wash Basins 1per 8 or part thereof   1 for up to 152 for 16 to 353 for 36 to 654 for 66 to 100 1 for up to 122 for 13 to 253 for 26 to 404 for 41 to 57 - -
V. Bath/showers 1 per 8 or part thereof 1 per 6 or part thereof - - 1 per 50 persons 1 per 50 persons
Notes. - (a) Toilet facilities for individual buildings in a market should be taken same as that for office buildings.
(b)Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors.
(c)Special toilet facilities for a large floating population of out of town buyers/ sellers, labour, drivers of vehicles for whom special toilet (public toilets).
Table 49:Bus Stations, Airports and RailwayStations
S No. Fixtures Junction Stations, Intermediate Stations and BusStations Terminal Railway and Bus Stations Domestic and International Airports
Males Females Males Females Males Females
I. Water Closets 3for up to 1000 add 1 per additional 1000 or part thereof 4for up to 1000 add 1 per additional 1000 or part thereof 4for up to 1000 add 1 per additional 1000 or part thereof 5for up to 1000 add 1 per additional 1000 or part thereof for 200 : 5for 400 : 9600 : 12800 : 16for1000 : 18 for 200 : 8for 400 : 15for 600 : 20for 800 : 26for1000 : 29
II. Ablution tab 1 in each watercloset1 water tap with draining arrangements shall beprovided for every 50 persons or part thereof in the vicinity ofwater closets and urinals
III. Urinals 4 for up to 1000 add 1 per additional 1000 - 6 for up to 1000 add 1 per additional 1000 - 1 per 40 or part thereof 4 for up to 1000 add 1 per additional 1000
IV. Wash Basins 1 per wc          
V. Bath/ showers 2 per 1000 or part thereof   3 per 1000 or part thereof   4 per 1000 or part thereof  
VI. Drinking Water Fountain or taps (in common lobbyfor male/female) 2 per 1000 or part thereof   3 per 1000 or part thereof   4 per 1000 or part thereof  
VII. Cleaner's sink 1 per toilet compartment with 3 wcs        
Notes. - (a) Some Water Closets (WC) may be Indian style, if desired.
(b)Male population may be assumed as three-fifth and female population as two-fifth.
(c)Separate provision shall be made for staff and workers.