building accompanied by - (a) the duly completed compliance forms together with check list of various components covered under rule (3) at the completion stage which ... power factor and power distribution losses; (vii) review the required check metering and monitoring system. (b) a list of the energy related building features
Grid Interactive System based on Net Metering) Regulations, 2019" (hereinafter referred to as "Net Metering Regulations, 2019")
2. Definitions, Abbreviations and Interpretations ... which generating plant is synchronised with the grid system; (6) "Check Meter" means a meter, which shall be connected to the same core
CERC" or "Central Commission" means the Central Electricity Regulatory Commission; (9) "Check Meter" means a meter, which shall be connected to the same core
receives electricity from the system of generating company or licensee; (i) `Check Meter' means a meter, which shall be connected to the same core ... referred; (v) `Standby Meter' means a meter connected to CT and VT, other than those used for main meter and check meter and shall
Operation of Meters) Regulations, 2006
7. Locations of meters.-
(1) The location of interface meters, consumer meters and energy accounting and audit meters shall ... licensees may install meters at additional locations in their systems depending upon the requirement. TABLE
Sl. No.
Stages
Main meter
Check meter
Stand by meter
Meters) Regulations, 2006
15. Meter failure or discrepancies.-
(1) Interface meters.- (a) Whenever difference between the readings of the Main meter and the Check meter ... relevant standard, the meter shall be immediately replaced with a correct meter. (c) In case where both the Main meter and Check meter fail
meter at site can remove the meter and replace the same by a tested meter duly tested in an accredited test laboratory. In addition, meters ... meter. The standard reference meter of better accuracy class than the meter under test shall be used for site testing of consumer meters
premises of the shipper. (7) The shipper may provide check meter, conforming to the applicable standard and specifications, at the delivery point in natural
Metering) Regulations, 2019" (hereinafter referred to as "Net Metering Regulations, 2019")
8. Metering Arrangement.
- 8.1. The metering system shall ... Solar Energy Meter shall have facility for recording meter readings using Meter Reading Instrument (MRI) or wireless equipment. 8.4 Check Meters shall be mandatory
Cross Border Trade of Electricity) Regulations, 2019
17. Metering Arrangements.
(1) Interface Meters (Main Meter, Check Meter and Standby Meter) shall be installed at both ... Agencies of both the countries shall confirm the availability of Main Meter, Check Meter and Standby Meter to System Operator of respective country. (3) Interface